Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement*

J Bone Joint Surg Am · 2000 · Classic · cited 788 times

Robert M. Urban, Joshua J. Jacobs, Michael J. Tomlinson, J. Gavrilovič, Jonathan Black, Michel Péoc’h

Department of Orthopedic Surgery, The Rush Arthritis and Orthopedic Institute, Rush-Presbyterian-St Luke's Medical…

Adult Reconstruction

SUMMARY — THE REDUCTIONMetallic and polyethylene wear particles from hip and knee replacements commonly disseminate systemically to lymph nodes, liver, and spleen, with higher prevalence after implant failure.
Abstract, as published

BACKGROUND: The importance of particles generated by wear and corrosion of joint replacement prostheses has been understood primarily in the context of the local effects of particle-induced periprosthetic osteolysis and aseptic loosening. We studied dissemination of wear particles in patients with total hip and knee replacement to determine the prevalence of and the histopathological response to prosthetic wear debris in the liver, spleen, and abdominal para-aortic lymph nodes. METHODS: Postmortem specimens from twenty-nine patients and biopsy specimens from two living patients with a failed replacement were analyzed. Specimens of tissue obtained from the cadavera of fifteen patients who had not had a joint replacement served as controls. The concentration of particles and the associated tissue response were characterized with the use of light microscopy of stained histological sections. Metallic particles were identified by electron microprobe analysis. Polyethylene particles were studied with the use of oil-red-O stain and polarized light microscopy. The composition of polyethylene particles was confirmed in selected cases by Fourier transform infrared spectroscopy and hot-stage thermal analysis. Twenty-one of the patients studied post mortem had had a primary total joint replacement. Eleven of them had had a hip prosthesis for a mean of sixty-nine months (range, forty-three to 171 months), and ten had had a knee replacement for a mean of eighty-four months (range, thirty-one to 179 months). The other eight patients studied post mortem had had a hip replacement in which one or more components had loosened and had been revised. The mean time between the initial arthroplasty and the time of death was 174 months (range, forty-seven to 292 months), and the mean time between the last revision procedure and the time of death was seventy-one months (range, one to 130 months). RESULTS: Metallic wear particles in the liver or spleen were more prevalent in patients who had had a failed hip arthroplasty (seven of eight) than in patients who had had a primary hip (two of eleven) or knee replacement (two of ten). The principal source of wear particles in the majority of these patients involved secondary nonbearing surfaces rather than wear between the two primary bearing surfaces as intended. In one living patient, dissemination of titanium alloy particles from a hip prosthesis with mechanical failure was associated with a visceral granulomatous reaction and hepatosplenomegaly, which required operative and medical treatment. Metallic wear particles were detected in the paraaortic lymph nodes in 68 percent (nineteen) of the twenty-eight patients with an implant from whom lymph nodes were available for study. In 38 percent (eleven) of all twenty-nine patients with an implant who were studied post mortem, metallic particles had been further disseminated to the liver or spleen, where they were usually found within small aggregates of macrophages occurring as infiltrates without apparent pathological importance. Polyethylene particles elicited a similar response. They were identified in the paraaortic lymph nodes of 68 percent (nineteen) of the twenty-eight patients and the liver or spleen of 14 percent (four) of the twenty-nine patients. The majority of the disseminated wear particles were less than one micrometer in size. Currently available methods lack the sensitivity and specificity necessary to detect very low concentrations of submicrometer polyethylene particles and probably underestimated the prevalence of polyethylene wear debris in the liver and spleen. CONCLUSIONS: In this study, systemic distribution of metallic and polyethylene wear particles was a common finding, both in patients with a previously failed implant and in those with a primary total joint prosthesis. The prevalence of particles in the liver or spleen was greater after reconstructions with mechanical failure. (ABSTRACT TRUNCATED)

Featured in the 2026-06-23 issue.

← Treatment of primary osteoarthritis of the hip. A comparison …United States Trends in Lumbar Fusion Surgery for Degenerativ… →

The Reduction is a free email digest of newly published orthopaedic literature — a handful of new papers in the subspecialties you choose, each summarized like this one. Subscribe free or browse the archive.