Tissue Pressure Measurements as a Determinant for the Need of Fasciotomy

Clin Orthop Relat Res · 1975 · Classic · cited 828 times

Thomas E. Whitesides, Thomas C. Haney, Kazuo Morimoto, Hiroshi Harada

Orthopaedic Trauma

SUMMARY — THE REDUCTIONMeasuring compartment tissue pressure aids early diagnosis of compartment syndrome; fasciotomy is generally indicated when pressure comes within 10 to 30 mm Hg of diastolic pressure, even with palpable distal pulses.
Abstract, as published

An experimental and clinical tehcnique of measuring tissue pressures within closed compartments demonstrates a normal tissue pressure is approximately zero mmHg, and increased markedly in compartmental syndromes. There is inadequate perfusion and relative ischemia when the tissue pressure within a closed compartment rises to within 10-30 mm Hg of the patient's diastolic blood pressure. Fasciotomy is usually indicated, therefore, when the tissue pressure rises to 40-45 mm Hg in a patient with a diastolic blood pressure of 70 mm Hg and any of the signs or symptoms of a compartmental syndrome. There is no effective tissue perfusion within a closed compartment when the tissue pressure equals or exceeds the patient's diastolic blood pressure. A fasciotomy is definitely indicated in this circumstance, although distal pulses may be present. The measurement of tissue pressure aids in the early diagnosis and appropriate treatment of compartmental syndromes.

Featured in the 2026-10-03 issue.

← Prospective multicenter trial of a plate for dorsal fixation …Femoral Neck Stress Fractures: An Updated Review. →

The Reduction is a free email digest of newly published orthopaedic literature — a handful of new papers in the subspecialties you choose, each summarized like this one. Subscribe free or browse the archive.