Does A Kinematically Aligned Total Knee Arthroplasty Restore Function Without Failure Regardless of Alignment Category?

Clin Orthop Relat Res · 2012 · Classic · cited 497 times

Stephen Miller Howell, Stacey J. Howell, Kyle T. Kuznik, Joe Cohen, Maury L. Hull

Adult Reconstruction

SUMMARY — THE REDUCTIONIn 214 kinematically aligned TKAs followed about 3 years, function was equally good across alignment categories and no catastrophic failures occurred, even though 75% had varus-outlier tibial components, easing concern about this technique.
Abstract, as published

BACKGROUND: Kinematically aligned TKA restores function by aligning the femoral and tibial components to the normal or prearthritic joint lines of the knee. However, aligning the components to the joint lines of the normal knee also aligns the tibial component in varus, creating concern that varus alignment might result in poor function and early catastrophic failure. QUESTIONS/PURPOSES: We therefore determined whether function and the incidence of catastrophic failure were different when the tibial component, knee, and limb alignment were in a specified normal range, varus outlier, or valgus outlier. METHODS: We prospectively followed all 198 patients (214 knees) who underwent TKAs between February and October 2008. We treated each knee in this cohort of patients with a kinematically aligned, cruciate-retaining prosthesis implanted using patient-specific guides. From a long-leg scanogram, we measured and categorized alignment of the tibial component as in range (≤ 0°) or a varus outlier (> 0°), alignment of the knee as in range (between -2.5° to -7.4° valgus) or a varus (> -2.5°) or valgus (< -7.4°) outlier, and alignment of the limb as in range (0° ± 3°) or a varus (> 3°) or valgus (< -3°) outlier. We assessed function using the Oxford Knee Score and WOMAC score, and reported catastrophic failure as the incidence of revision attributable to loosening, wear, and instability of the femoral or tibial components. The minimum followup was 31 months (mean, 38 months; range, 31-43 months). RESULTS: The mean Oxford Knee Score of 43 and WOMAC score of 92 were similar between the three alignment categories. The incidence of catastrophic failure in each alignment category was zero. CONCLUSIONS: Kinematically aligned TKA restores function without catastrophic failure regardless of the alignment category. Because 75% of patients had their tibial component categorized as a varus outlier and also had high function and a zero incidence of catastrophic failure, the concern that kinematic alignment compromises function and places the components at a high risk for catastrophic failure is unfounded and should be of interest to surgeons committed to cutting the tibia perpendicular to the mechanical axis of the tibia. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Featured in the 2026-10-25 issue.

← Custom Triflange Acetabular Components in Revision Total Hip …Bundled Payments in Total Joint Arthroplasty: Targeting Oppor… →

The Reduction is a free email digest of newly published orthopaedic literature — a handful of new papers in the subspecialties you choose, each summarized like this one. Subscribe free or browse the archive.