Validation of Digital Visual Analog Scale Pain Scoring With a Traditional Paper-based Visual Analog Scale in Adults

J Am Acad Orthop Surg Glob Res Rev · 2018 · Classic · cited 1,169 times

Domenica A. Delgado, Bradley S. Lambert, Nickolas Boutris, Patrick C. McCulloch, Andrew B. Robbins, Michael R. Moreno, et al.

Houston Methodist Hospital, Houston, TX (Ms. Delgado, and Dr. Moreno)

General Orthopaedics

SUMMARY — THE REDUCTIONDigital VAS pain scores via laptop and mobile phone showed no clinically meaningful difference from traditional paper VAS, supporting digital pain assessment as a valid alternative in practice.
Abstract, as published

Background: The visual analog scale (VAS) is a validated, subjective measure for acute and chronic pain. Scores are recorded by making a handwritten mark on a 10-cm line that represents a continuum between “no pain” and “worst pain.” Methods: One hundred consecutive patients aged ≥18 years who presented with a chief complaint of pain were asked to record pain scores via a paper VAS and digitally via both the laptop computer and mobile phone. Ninety-eight subjects, 51 men (age, 44 ± 16 years) and 47 women (age, 46 ± 15 years), were included. A mixed-model analysis of covariance with the Bonferroni post hoc test was used to detect differences between the paper and digital VAS scores. A Bland–Altman analysis was used to test for instrument agreement between the platforms. The minimal clinically important difference was set at 1.4 cm (14% of total scale length) for detecting clinical relevance between the three VAS platforms. A paired one-tailed Student t-test was used to determine whether differences between the digital and paper measurement platforms exceeded 14% (P < 0.05). Results: A significant difference in scores was found between the mobile phone–based (32.9% ± 0.4%) and both the laptop computer– and paper-based platforms (31.0% ± 0.4%, P < 0.01 for both). These differences were not clinically relevant (minimal clinically important difference <1.4 cm). No statistically significant difference was observed between the paper and laptop computer platforms. Measurement agreement was found between the paper- and laptop computer–based platforms (mean difference, 0.0% ± 0.5%; no proportional bias detected) but not between the paper- and mobile phone–based platforms (mean difference, 1.9% ± 0.5%; proportional bias detected). Conclusion: No clinically relevant difference exists between the traditional paper-based VAS assessment and VAS scores obtained from laptop computer– and mobile phone–based platforms.

Featured in the 2026-07-29 issue.

← Ligamentous restraints to anterior-posterior drawer in the hu…The Role of Electronic Learning in Orthopaedic Graduate Medic… →

The Reduction is a free email digest of newly published orthopaedic literature — a handful of new papers in the subspecialties you choose, each summarized like this one. Subscribe free or browse the archive.