Plate Fixation of Distal Radius Fractures: What Type of Plate to Use and When?

Hand Clin · May 2021 · Review

Schindelar LE, Ilyas AM

The Rothman Orthopaedic Institute, Thomas Jefferson University, Rothman Institute

Hand & Upper Extremity Orthopaedic Trauma

SUMMARY — THE REDUCTIONThis review outlines when to use volar, dorsal, or bridge plates for distal radius fractures based on fracture pattern, patient factors, and surgeon experience.
Abstract, as published

There are several options for plate fixation of distal radius fractures. Volar plating has broad applicability and consistent outcomes, and thus is the most commonly used plate type. Dorsal plates are advantageous for specific fracture patterns, and can provide direct fracture reduction and buttressing, but may be prominent and can cause tendon irritation. Bridge plates offer an alternative to external fixation while avoiding the complications with prominent hardware, because they span highly comminuted fractures and can be used for immediate weight bearing; however, they require plate removal. Choice of plate fixation should depend on fracture type, patient factors, and surgeon experience.

Featured in the 2026-08-16 issue.

← Fingertip Infections.The stiff proximal interphalangeal joint - an unsolved problem? →

The Reduction is a free email digest of newly published orthopaedic literature — a handful of new papers in the subspecialties you choose, each summarized like this one. Subscribe free or browse the archive.