The Alpha Angle.

J Bone Joint Surg Am · Sep 16 2024 · Review

Ekhtiari S, Fairhurst O, Mainwaring L, Khanduja V

School of Clinical Medicine, University of Cambridge, Cambridge, United Kingdom

Sports Medicine

SUMMARY — THE REDUCTIONThis review discusses limitations of the alpha angle for quantifying cam lesions, advocating best-fit circle measurement on multiple views and noting promise of newer 3D and dynamic imaging techniques.
Abstract, as published

➢ The alpha angle was originally defined on magnetic resonance imaging (MRI) scans, using a plane, parallel to the axis of the femoral neck. However, much of the literature on the alpha angle has used radiographs or other imaging modalities to quantify the alpha angle.➢ The measurement of the alpha angle can be unreliable, particularly on radiographs and ultrasound.➢ If radiographs are used to measure the alpha angle, the circle of best-fit method should be used on multiple different views to capture various locations of the cam lesion, and "eyeballing" or estimating the alpha angle should be avoided.➢ The cam lesion is a dynamic and 3-dimensional (3D) problem and is unlikely to be adequately defined or captured by a single angle.➢ Modern technology, including readily available 3D imaging modalities, as well as intraoperative and dynamic imaging options, provides novel, and potentially more clinically relevant, ways to quantify the alpha angle.

Featured in the 2026-09-20 issue.

← The synergistic action of the anterior cruciate ligament and …Radial extracorporeal shockwave therapy (rESWT) for patients … →

The Reduction is a free email digest of newly published orthopaedic literature — a handful of new papers in the subspecialties you choose, each summarized like this one. Subscribe free or browse the archive.