Proximal Phalanx Intramedullary Fixation Configurations: A Comparative Biomechanical Cadaveric Study.

Hand (N Y) · Aug 26 2026 · Recent

Peszek A, Richman EH, Rakowski DR, Kahan R, Wittholt H, Baldini T, et al.

University of Colorado School of Medicine, Aurora, USA

Hand & Upper Extremity

SUMMARY — THE REDUCTIONIn cadaveric proximal phalanx fractures, threaded intramedullary nails in "X" or "Y" configurations provided significantly greater construct stiffness than K-wires or "I"-configuration nails, with similar load to failure across groups.
Abstract, as published

BACKGROUND: Threaded intramedullary nails offer a fixation option for proximal phalanx fractures with the advantage of immediate mobilization, avoiding secondary hardware removal, and decreased complications associated with exposed pins. There are currently limited data comparing the strength of intramedullary devices across various configurations with the traditional fixation method of Kirschner wires (K-wires). This study compared the biomechanical strength of intramedullary nail fixation (INF) in an "I," "Y," or "X" configuration or 2 Kirschner wires in an "X" configuration for transverse proximal phalanx fractures.

METHODS: Forty cadaveric proximal phalanges with simulated transverse fractures were randomized to 1 of 4 fixation groups: INF in an "I," "Y," or "X" configuration or 2 K-wires in an "X" configuration. The specimens were subjected to apex dorsal 3-point bending to failure using servohydraulic testing. Peak load to failure and stiffness were recorded. Analysis of variance was used to compare means between groups.

RESULTS: No statistically significant differences in mean peak load to failure were detected between groups. Stiffness differed among groups, with the INF "X" configuration producing the stiffest construct (mean stiffness, 210 N/mm), significantly stiffer than all other groups. The second stiffest construct was the INF "Y" configuration (150.9 N/mm), which was significantly higher than both the INF "I" construct (107.7 N/mm) and the K-wire construct (91.8 N/mm). There was no significant difference between the INF "I" construct and the K-wire construct.

CONCLUSION: Threaded INF in "X" or "Y" configurations offers superior stiffness compared to K-wire and "I" INF for proximal phalanx fractures.

Featured in the 2026-08-27 issue.

← Reverse Total Wrist Arthroplasty: New Design and Biomechanica…Distal Radial Fracture as an Early Marker of Bone Fragility: … →

The Reduction is a free email digest of newly published orthopaedic literature — a handful of new papers in the subspecialties you choose, each summarized like this one. Subscribe free or browse the archive.