Increased Risk of Fixation Failure With Two 3.5 Versus 4.5 Millimeter Solid Bicortical Screws for Tibial Tubercle Osteotomy.

Arthroscopy · Sep 12 2026 · Recent

Varady NH, Neijna AG, Terry HL, Reddy RP, Gomoll AH, Strickland SM

Department of Sports Medicine, Hospital for Special Surgery, New York, U.S.A

Sports Medicine Orthopaedic Trauma

SUMMARY — THE REDUCTIONIn 398 tibial tubercle osteotomies, two 3.5 mm screws had significantly higher fixation failure rates than two 4.5 mm screws, suggesting screw size is a modifiable risk factor.
Abstract, as published

PURPOSE: To assess the association between screw size and fixation failure after tibial tubercle osteotomy (TTO).

METHODS: Patients undergoing primary TTO from 2015 to 2024 by 2 patellofemoral surgeons fixed with two 3.5 mm or two 4.5 mm solid bicortical screws were compared. The primary outcome was fixation failure (i.e., fracture, nonunion, or symptomatic delayed union requiring operative intervention) by 6 months. Patient demographic and surgical factors were collected. Univariate and multivariable adjusted analyses controlling for known and/or theoretical risk factors for overall complications after TTO were performed. Secondary analysis assessed the association between other patient/surgical factors and fixation failure.

RESULTS: There were 398 patients with a mean follow-up of 2.2 years (mean age 28.3 ± 9.6 years; 74.4% women). The overall rate of fixation failure was 2.0%, occurring at a mean of 3.3 ± 1.8 months postoperatively. Patients undergoing TTO with 3.5 mm screws were significantly more likely to experience fixation failure than patients undergoing TTO with 4.5 mm screws (7.9% vs 1.4%, P = .03); results were even more pronounced when limiting analysis to the 296 female patients (7.9% vs 0.78%, P = .02). Results held in all adjusted analyses, including when controlling for age, sex, smoking, concomitant procedures, and TTO distalization (which was more common in the 3.5 mm group), among other factors (odds ratio 8.1, 95% confidence interval 1.1-59.8, P = .04). No other patient or surgical factor, including distalization, was associated with fixation failure (P ≥ .15 for all).

CONCLUSIONS: Compared with two 4.5 mm screws, two 3.5 mm screws were associated with a significantly increased risk of fixation failure after TTO, even after adjusting for patient and surgical factors. Although fixation failure overall remains rare after TTO, screw size may be a modifiable risk factor to reduce the risk of this devastating complication.

LEVEL OF EVIDENCE: Level III, retrospective comparative case series.

Featured in the 2026-09-19 issue.

← Complications after anterior closing-wedge high tibial osteot…Labral Repair With Concomitant Endoscopic Gluteus Medius and/… →

The Reduction is a free email digest of newly published orthopaedic literature — a handful of new papers in the subspecialties you choose, each summarized like this one. Subscribe free or browse the archive.