An Artificial Intelligence-Based Preoperative Planning System for High Tibial Osteotomy Significantly Enhances Planning Speed With Comparable Accuracy to Surgeons.

Arthroscopy · Sep 19 2026 · Recent

Li S, Li Z, Zhang H, Chen Y, Miao Z, Li L, et al.

Department of Orthopedics, Qilu Hospital of Shandong University, Jinan, China

Sports Medicine

SUMMARY — THE REDUCTIONAn AI planning system for open wedge high tibial osteotomy measured alignment and correction angles as accurately as attending surgeons while cutting planning time from about 4 minutes to 9 seconds per image.
Abstract, as published

PURPOSE: To develop an artificial intelligence-based system capable of measuring preoperative alignment parameters, calculating correction angles, and visualizing outcomes for open wedge high tibial osteotomy (OWHTO) and to validate the accuracy and efficiency of the system in clinical cases.

METHODS: Between January and December 2023, standing hip-to-ankle radiographs from patients with varus knee osteoarthritis were retrospectively collected as the development cohort. The OWHTO auxiliary planning system (OAPS) was developed using a UNet convolutional neural network to detect 28 anatomical landmarks. The system was validated against manual measurements by attending surgeons and further evaluated through an external validation cohort across 2 institutions to compare accuracy and efficiency among junior residents using manual, semiautomatic, and OAPS-assisted methods.

RESULTS: The study included 346 knees for development and an external validation cohort of 110 knees. On the test set, the OAPS achieved a mean radial error of 2.703 pixels and a successful detection rate at the 6-pixel threshold of 0.951. For hip-knee-ankle and correction angles, the mean absolute errors were 0.47° (95% CI: 0.39°-0.56°) and 0.43° (95% CI: 0.36°-0.51°), respectively. No significant differences were found between OAPS and attending surgeons across all alignment parameters (P > .05). OAPS processed each image in 9.27 seconds, which was significantly faster than the 4.30 minutes required for manual planning on the test set (P < .001). External validation confirmed that OAPS-assisted resident measurements matched attending-level accuracy and were significantly faster than manual and semiautomatic methods.

CONCLUSIONS: The artificial intelligence-based OAPS enables accurate, efficient preoperative planning for OWHTO, achieving measurement precision comparable to experienced surgeons while significantly reducing planning time.

CLINICAL RELEVANCE: By automating anatomical measurement and planning, the OAPS reduces interobserver variability and enhances preoperative plan efficiency within OWHTO workflows, streamlining the preparation phase for surgical teams.

Featured in the 2026-10-08 issue.

← Effects of Losartan on Musculoskeletal Tissues : Basic Scienc…Postoperative Supraspinatus Muscle Volume Restoration Is Asso… →

The Reduction is a free email digest of newly published orthopaedic literature — a handful of new papers in the subspecialties you choose, each summarized like this one. Subscribe free or browse the archive.