Ten-year insert wear and the migration of uncemented tibial and femoral components with either conventional polyethylene or sequentially annealed highly crosslinked polyethylene: a blinded randomized controlled trial using radiostereometric analysis.

Bone Joint J · Oct 01 2026 · Recent

de Ridder R, Kaptein BL, Pijls BG, Nelissen RGHH, Pasma JH, Oomen R, et al.

Reinier Haga Orthopaedic Centre, Zoetermeer, Netherlands

Adult Reconstruction

SUMMARY — THE REDUCTIONIn this 10-year randomized trial of uncemented TKA, highly crosslinked polyethylene showed no progressive wear after year five while conventional polyethylene wear continued, and component migration and outcomes were similar between groups.
Abstract, as published

AIMS: The aims of this randomized controlled trial (RCT) was to compare the long-term insert wear and migration of the tibial and femoral components between highly crosslinked polyethylene (HXLPE) inserts and conventional polyethylene (PE) inserts in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA).

METHODS: A double-blinded RCT was conducted including 96 TKAs. The wear of the insert, and migration of both the tibial and femoral components, was measured with model-based radiostereometric analysis up to ten years postoperatively. Patient-reported outcome measures (PROMs) were collected preoperatively and at follow-up.

RESULTS: There was no progression of (medial) wear (from 0.15 mm at five years to 0.13 mm at ten years) for the HXLPE group after five years, whereas the wear rate increased for the PE group (from 0.22 mm at five years to 0.46 mm at ten years). There was no clinically relevant difference in terms of migration of the tibial and femoral component or PROMs between the HXLPE and PE groups at ten years. Migration of the tibial component (maximal total point motion; MTPM) after the ten-year follow-up for the HXLPE group was 0.99 mm (95% CI 0.83 to 1.18), and for the PE group, was 1.05 mm (95% CI 0.87 to 1.24). Migration of the femoral component (MTPM) after the ten-year follow-up for the HXLPE group was 1.16 mm (95% CI 0.99 to 1.35), and for the PE group, MTPM was 1.04 mm (95% CI 0.87 to 1.22).

CONCLUSION: There was no discernible increased wear for the HXLPE group after five years, whereas the wear for the PE group continued. After the initial migration, the uncemented TKA components remain stable at the ten-year follow-up. The use of HXLPE inserts are safe, when used in uncemented TKA, when considering wear and component migration.